Friday, 11 December 2009

Teamviewer 4 or 5

Now that Teamviewer 5 is available to download then it is very easy to install this version. However, the commercial license for Hawkstone Design is version 4 and there are no material benefits from using version 5. Teamviewer do not allow Version 4 and Version 5 to mix.  The link below will start TeamViewer 4 with the Hawkstone Design commercial license on your PC.

http://www2.hawkstonedesign.co.uk/downloads/TeamviewerQS.exe


_______________________________________________

Tuesday, 8 December 2009

VCATracer Shape Editor

Version 1.20 also includes a shape editor. An existing shape can have the Nasal, Temporal, Upper or Lower quadrants increased or decreased. Alternatively a correction can be applied to the whole shape. When the shape is saved, it is saved with the original name + "(Copy)".

___________________________

Friday, 27 November 2009

VCATracer 1.20

V1.20 VCATracer updates

  • Records Serial Number, Model, Machine ID in the OMA file that is sent.
  • Indicates if and when the trace was uploaded.
  • Support translation into different languages
  • Downloads new configuration files from the web site so if lab web site moves etc then this is picked up and traces are sent to the new site.
  • Installer does not overwrite installation with an older version.
  • First pass at supporting Nidek mode in the tracer.

_______________________________________________

Tuesday, 24 November 2009

Solenzare V087/V088

V087 - As the number ofi users is increasing, it is becoming more important that resources are managed efficiently. One resource that is causing problems is the number of database connections so the program will automatically release the database connection when idle on the main menu for more than 2 minutes. The time out on this form is now increased to 30 minutes.

V088 - Print via PDF added to the view orders page.
___________________________________________________

Saturday, 7 November 2009

FTP

FTP to be set to Active.
There have been some problems with FTP access to the Hawkstone Design web site. The ISP says that access has to be in Active mode so if Passive is ticked in a setting then it should be unticked. This also applies to the VCATracer program but this should be set to use the PHP Script that has been developed as a replacement for FTP.

Other programs are being rewritten to replace FTP access where possible.
__________________________________________________

V086 Statistics

Statistics:
When signing in as "Admin" user then there is a button to show a statistics screen. This shows orders by hour, orders per day, orders per customer, number of lenses by name, type, design

There is also a link to this Blog.

____________________________________

Monday, 26 October 2009

Solenzara V085

V084 - time out redesigned so that order input returns to main menu after a few minutes and saves current input in drafts. The main menu closes "gracefully" after 10 minutes of inactivity.

V085 - User and Lab configuration information is backed up on the web site.
___________________________________

Friday, 16 October 2009

Web Services

The Web service has been revised and the documentation updated
Webservices.pdf
There is additional and relevant documentation
Passing information in URL
CSV Data file formats.

Enjoy
_____________________________________________________

Tuesday, 29 September 2009

Solenzara V083

Now allows \ & ? / etc in the reference but the reference still has to be unique.

Wednesday, 16 September 2009

The VCATracer program now requires a daily control shape to be run. This control shape is also uploaded to the web site so that the lab can check that the tracer is being correctly maintained.

When the program starts for the first time on that day, then the user is asked to trace the control shape. This should be the calibration jog if it is available and if not then it should be a sturdy frame.

_____________________________________________________


Tuesday, 18 August 2009

Raptor V1.13

The option to print orders out for faxing has been added. The print layout is defined using the Hawkstone Design layout manager program.

15.08.09

V080

This version has extra options in lab configuration data to set defaults for edge thickness and to define which special instructions are supported.

15.08.09

Saturday, 1 August 2009

Raptor 1.12

Updates for
Creating general CSV file for sending to non-Hawkstone members
Allow printing of orders. This uses the Layout manager.
Allow multiple accounts for one supplier - you enter the accounts in the account field separated with : eg 123456:123457 and also for the password.


____________________________________

Thursday, 16 July 2009

V079


  • This version sets database access to retrieve records for the user only, an extra security layer and also to save on memory.

  • There is also option for Admin users to delete old orders in the Browser screen.

_____________________________________________

Sunday, 28 June 2009

V077

This version incorporated a multitude of background changes primarily to
- to share common code between web application and web services
- to reduce memory size

as well as minor changes to the layout.

____________________________________________________________

Tuesday, 23 June 2009

Not registered link

Hi

The latest version has a not registered link. The link for this page is filled in on the configuration page which runs the html (modified for each lab) which in turn redirects to your log in page.

David


To reset iframe use the following javascript

if (top.location != location) top.location.href = location.href;

To redirect to new page

Back from travels abroad. In response to several requests, here is a document describing how the programs are linked together. There is also xfrprinter to print xfr files naturally.


How the programs are linked

Thursday, 4 June 2009

Solenzara V0.76

In this update:

Multi-language improved

There were necessary changes required for running multiple languages in the same web application.

Inbox processing Improved.

The processing of the Inbox has been improved so as to automate and to better select the expected lenses and treatments.

Diameter calculation improved.

The diameter calculation has been improved to take into account any decentration specified in the ranges data.

Not registered link.

A not-registed link has been added to the lab configuration screen which points to a page on the calling web site.

_________________________________________________________

Raptor 1.06

There have been more updates to this program so that it communicates with Web services and there is improved linkage with Essilor including presize data.

XFRPrinter

A new program has been released to Print XFR files.

This program uses "Layout Manager" program to visually design the print out. The layout manager program will be used for all forthcoming print program so that you are in control of all the print outs made.

If you are using program PrintXFR from another source then please contact for advice on how to upgrade.

Tuesday, 12 May 2009

V71/72

Two quick updates.

V71 - order numbers in v70 are now prefixed with zeros, this caused the tracking for older orders to be misplaced. A quick fix to handle this. No treatment button remains active until all treatments have been chosen.

V72 - Added first draft of Optisoft catalogue and feedback from Optinet / Essilor

Monday, 4 May 2009

Raptor 1.02

Update to fix the following:

Remove Order button on the list of orders to sent now operates correctly.

There was a problem with height direction which is now corrected.
_________________________________________

Friday, 1 May 2009

V0.70

Included in this version are:

Axis with .5 decimal was not handled properly



View Job Status shows latest jobs first



Job order numbers are now prefixed with 0 to make 6 digit codes but this had an unintened consequence for job tracking in that there was not a match on the order numbers.


A link for PMS catalogue download has been established.
__________________________________________

Tuesday, 28 April 2009

V069

The program has been updated so that orders more than 3 months old are removed.

The tracking has been updated, there was a pecularity in that to get the absolute latest, you do not need to go into Job Status, Exit and Back in again. Now it is updated once you enter Job Status.

Outside Range Checking. There is now an option to check the range but to allow through with a warning (confirmed by customer) if outside the range.

__________________________________________

Monday, 27 April 2009

Raptor 1.01

This is updated to use any conversions that had been set up in ediconv as the default conversion.

Thursday, 23 April 2009

V67

Bug fixes:



Single Eye:
If no power entered in right eye but right lens was selected then sent plano power for right eye.

Place Order:
This did not always respond on first press - a different implementation has been tried.
______________________________________________________________



Sunday, 19 April 2009

V66

Fix for some problems reported.

a) If program launched with user=...&pass... then program looked to create a shape from the launching program even if one did not exist.

b) In View Job Status, if there was one item on the last page then the next / last buttons were not enabled

c) Further improvements for automatic processing when EDI files placed in the inbox.

d) Completion of the Hoya interface file. Essilor due for development this week.

__________________________________

Thursday, 9 April 2009

V065 new features - preview

New features in V065.



After a little break, it is back to the development.




Shapes. As well as the standard shapes 1-8, there is option for the input of user defined shape. This is in preparation for users to be able to digitize their own shapes but it is also useful for when there is a shape in an electronic file.



Electronic file.


The Inbox folder has been rewritten. This will allow external systems to pass files into the Inbox and then the user can complete the order. In this preview screen, there are a number of files uploaded. The lens and treatment codes /descriptions are shown along with the proposed mapping based on previous usage. The mapping can be done at the user end by downloading the catalogue. There are options for automatic or manual process.







Lens Selection.


Added a warning label if lens selected but treatments have not. There was some confusion as to why the Accept button was not enabled.



Freeform Macros.

A new screen to allow the input of additional freeform questions has been added. The lab can define the additional questions in an updated version of the lab configuration software.



Physical / Optical Dia.

When the ranges were added there was a field for specifying decentration of fitting cross. This leads to calculation of Optical diameter and this is shown in the input screen.

Intelligent Monitoring of RX.
In response to feedback, the method of disabling / enabling the axis when a cyl is present has been changed.

Monday, 30 March 2009

Suggestions

The following suggestions have been proposed and will be done.

Tracer Program.
Filter to found previous traces quickly

A step by step method as well as current method.
1) Trace frame
2) Enter reference
3) Enter DBL (if needed)
4) Upload

A calibration / control routine

Solenzara
Add button to view user guide
Create FAQ and also a link to it

________________________________________________

Saturday, 21 March 2009

V064

Fix stange quirk in lens selection where if new selected lens had the same number of matching items in the list then the list was not updated on the screen until the mouse was passed over the list - suspect down to Internet Explorer trying to be clever!

Thursday, 19 March 2009

V0.63

A small update but
a) if manufacturer list provided in lens selection then this acts more like a filter on the design rather than working like the other list boxes.
b) tidy up some problems with single eye in calculation of diameter
c) if lens was set to be non-tintable then it was asking for tint to be confirmed - doh!

Tuesday, 17 March 2009

Setting Up Ranges



Documentation for configuring ranges is in Ranges


And the User Guide for Web Ordering program is in
User Guide
(link corrected 18.03.09 14:20)

V 0.62

Updates in this version.



Ranges: This will be a separate entry to explain how to add / use ranges.



DBL Validation: Fixed a bug on this.



Copy Last / Repeat Last : A button has been added alongside the reference to allow the last order to repeated.



Configuration: A second screen has been added with more options - (needs a good tidy up at some time) eg disallow Exec on remote edge.



Automatic of + in Rx screen - there has been some feedback that this affects typing in the . in 2.25. It is now configurable so we will see how it goes.



Copying of right diameter to left diameter - remove the annoying error message halfway through.



Minimum Depth on remote edge orders- this can now be set.









labweb blog debut

Hi

As promised here is a blog to
a) record updates to the program
b) capture suggestions for problems

Let's see how it goes?